Basics of Wet Analysis Technique: Buret

A buret is used to deliver solution in precisely-measured, variable volumes. Burets are used primarily for titration, to deliver one reactant until the precise end point of the reaction is reached.

Filling Buret

To fill a buret, close the stopcock at the bottom and use a funnel. You may need to lift up on the funnel slightly, to allow the solution to flow in freely.

Filling Buret using disposable transfer pipet

You can also fill a buret using a disposable transfer pipet. This works better than a funnel for the small, 10 mL burets. Be sure the transfer pipet is dry or conditioned with the titrant, so the concentration of solution will not be changed.Before titrating, condition the buret with titrant solution and check that the buret is flowing freely. To condition a piece of glassware, rinse it so that all surfaces are coated with solution, then drain. Conditioning two or three times will insure that the concentration of titrant is not changed by a stray drop of water.

 buret31.gif

Check the tip of the buret for an air bubble. To remove an air bubble, whack the side of the buret tip while solution is flowing. If an air bubble is present during a titration, volume readings may be in error.

buret42.gif

 buret5.gif

 Rinse the tip of the buret with water from a wash bottle and dry it carefully. After a minute, check for solution on the tip to see if your buret is leaking. The tip should be clean and dry before you take an initial volume reading.


 

 buret6.gif

 buret7.gif

When your buret is conditioned and filled, with no air bubbles or leaks, take an initial volume reading. A buret reading card with a black rectangle can help you to take a more accurate reading. Read the bottom of the meniscus. Be sure your eye is at the level of meniscus, not above or below. Reading from an angle, rather than straight on, results in a parallax error. 

buret8.gifburet9.gif

Deliver solution to the titration flask by turning the stopcock. The solution should be delivered quickly until a couple of mL from the endpoint.

The endpoint should be approached slowly, a drop at a time. Use a wash bottle to rinse the tip of the buret and the sides of the flask. Your TA can show you how to deliver a partial drop of solution, when near the endpoint.

 buret10.gif

courtessy: darthmoth.edu

CO.CC:Free Domain

About these ads

  1. This topic is quite trendy on the Internet right now. What do you pay attention to when choosing what to write about?

    • Hi six pac..something, i have to ensure i have put the author’s name after picking the topic from someone else lol. Yeah I just like to learn new things, thanks for your visit..

  2. tata elvis bah

    Hi,
    It was interesting coming across your publications. Am a student researcher in a less developed country(Cameroon).Please kindly give me the laboratory protocol to use in determining the concentrations of heavy metals in sediments by wet analysis.

    • hi tata…, i believe i am too late for you to reply, but i suggest you using ash analysis or AAS depend on what the sediment is made of, you need to burn the sediment in a burner if the sediment is carbon related matter. But if the sediment is anorganic matter, i think you should break it down completely before until you get homogenous solution with the solute to analyse it using AAS. It is a taugh work i believe, good luck great scientist!




Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s



Follow

Get every new post delivered to your Inbox.

%d bloggers like this: